<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>23015 Archives - Ayalytical</title>
	<atom:link href="https://ayalytical.com/product-category/method/en/23015/feed/" rel="self" type="application/rss+xml" />
	<link>https://ayalytical.com/product-category/method/en/23015/</link>
	<description>Ayalytical Instruments, Inc.</description>
	<lastBuildDate>Tue, 17 Dec 2024 22:17:16 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.8.2</generator>

<image>
	<url>https://ayalytical.com/wp-content/uploads/2024/11/cropped-ayalytical-logo-molecule-dark-32x32.png</url>
	<title>23015 Archives - Ayalytical</title>
	<link>https://ayalytical.com/product-category/method/en/23015/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Cloud And Pour Point</title>
		<link>https://ayalytical.com/product/cloud-and-pour-point/</link>
		
		<dc:creator><![CDATA[Juan Ayala]]></dc:creator>
		<pubDate>Tue, 02 Jan 2024 14:30:23 +0000</pubDate>
				<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>The versatile design of the Cloud and Pour Point Apparatus and conventional refrigerators guarantees compliance with requirements ASTM D97, IP 15, and ISO 301 for all petroleum products, including black specimens, cylinder stock, and nondistallate fuel oil; ASTM D2500, IP 219, EN 23015, and ISO 3015 for petroleum products and biodiesel fuels that are transparent [&#8230;]</p>
<p>The post <a href="https://ayalytical.com/product/cloud-and-pour-point/">Cloud And Pour Point</a> appeared first on <a href="https://ayalytical.com">Ayalytical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The versatile design of the Cloud and Pour Point Apparatus and conventional refrigerators guarantees compliance with requirements ASTM D97, IP 15, and ISO 301 for all petroleum products, including black specimens, cylinder stock, and nondistallate fuel oil; ASTM D2500, IP 219, EN 23015, and ISO 3015 for petroleum products and biodiesel fuels that are transparent in layers 40 mm in thickness , and with a cloud point below 49 C; and ASTM D5853 and IP 441 for determining the pour point of crude oils at temperatures as low as -36C.</p>
<p>The cloud and pour point apparatus is available in 6 models: model 490/HS/140 with 4 positions operating at temperatures as low as -69C; model 500/S with 4 positions each for 4 different temperatures (0, -18, -33, and -51C); model 510/S with 4 positions each for 3 different temperatures (0, -18, and -33C); model 520/S with 4 positions each for 5 different temperatures (0, -18, -33, 52, and -69C); model 530/S with 4 positions each for 6 temperatures ( 50, 0, -18, -33, -33, -51, and -69C); and model 540, the conventional cloud and pour point apparatus, operating at temperatures as low as -69C with dry ice.</p>
<p>Designed for simple use at extremely low temperatures, the cloud and pour point refrigerators are each equipped with an automatic defrosting mechanism and a digital thermoregulator fitted with a PT100 A temperature probe, ensuring stable temperatures as low as -69 C. Additional features of the cloud and pour point apparatus include a glossy black PVC cover with small stand-by covers and aluminum blocks with holes to accommodate graduated jars.</p>
<p>The cloud point refrigerators are equipped with four wheels and brakes for easy mobility around thelaboratory. The instruments are sealed with an anti-acid epoxidic coat, preventing corrosive damage andensuring durability for years to come. Because operator safety is crucial, the cloud point tester&#8217;s refrigerators are fitted with an earth leakage circuit, and refrigerant gases are CFC-free.</p>
<p>The post <a href="https://ayalytical.com/product/cloud-and-pour-point/">Cloud And Pour Point</a> appeared first on <a href="https://ayalytical.com">Ayalytical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
		<item>
		<title>DR7</title>
		<link>https://ayalytical.com/product/dr5/</link>
		
		<dc:creator><![CDATA[Juan Ayala]]></dc:creator>
		<pubDate>Tue, 02 Jan 2024 12:40:17 +0000</pubDate>
				<guid isPermaLink="false"></guid>

					<description><![CDATA[<p>The DR6 and DR7 series are fully automated cold property analyzers. They are fully compliant withASTM D97, D2500, D5853, D6371, D6422 etc. It is the latest version of the DR4 and DR5 series. They can test either cloud and pour point,CFPP, or freeze point.The DR6 and DR7 series has a state-of-the-art cooling system that allows [&#8230;]</p>
<p>The post <a href="https://ayalytical.com/product/dr5/">DR7</a> appeared first on <a href="https://ayalytical.com">Ayalytical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<p>The DR6 and DR7 series are fully automated cold property analyzers. They are fully compliant withASTM D97, D2500, D5853, D6371, D6422 etc. It is the latest version of the DR4 and DR5 series. They can test either cloud and pour point,CFPP, or freeze point.The DR6 and DR7 series has a state-of-the-art cooling system that allows a wide temperature range from -120C to  35C. It cools at a rate of 1 C in 5 seconds or less. It maintains temperature of  &#8211; 1C.</p>
<p>The DR6 and DR7 series automated analyzers are nearly identical in design and configuration. The only difference is the number of test positions. The DR6 is a single test position instruments, while the DR7 series signifies dual test positions.</p>
<p>All DR6 and DR7 instruments come fully loaded with all necessary accessories ready to run at full capacity out of box.</p>
<p>The post <a href="https://ayalytical.com/product/dr5/">DR7</a> appeared first on <a href="https://ayalytical.com">Ayalytical</a>.</p>
]]></content:encoded>
					
		
		
			</item>
	</channel>
</rss>
