<?xml version="1.0" encoding="UTF-8"?><rss version="2.0"
	xmlns:content="http://purl.org/rss/1.0/modules/content/"
	xmlns:wfw="http://wellformedweb.org/CommentAPI/"
	xmlns:dc="http://purl.org/dc/elements/1.1/"
	xmlns:atom="http://www.w3.org/2005/Atom"
	xmlns:sy="http://purl.org/rss/1.0/modules/syndication/"
	xmlns:slash="http://purl.org/rss/1.0/modules/slash/"
	>

<channel>
	<title>K 12541-7 Archives - Ayalytical</title>
	<atom:link href="https://ayalytical.com/product-category/method/jis/k-12541-7/feed/" rel="self" type="application/rss+xml" />
	<link>https://ayalytical.com/product-category/method/jis/k-12541-7/</link>
	<description>Ayalytical Instruments, Inc.</description>
	<lastBuildDate>Wed, 21 Oct 2026 17:01:38 +0000</lastBuildDate>
	<language>en-US</language>
	<sy:updatePeriod>
	hourly	</sy:updatePeriod>
	<sy:updateFrequency>
	1	</sy:updateFrequency>
	<generator>https://wordpress.org/?v=6.9.6</generator>

<image>
	<url>https://ayalytical.com/wp-content/uploads/2024/11/cropped-ayalytical-logo-molecule-dark-32x32.png</url>
	<title>K 12541-7 Archives - Ayalytical</title>
	<link>https://ayalytical.com/product-category/method/jis/k-12541-7/</link>
	<width>32</width>
	<height>32</height>
</image> 
	<item>
		<title>Micro-Z ULSD Analyzer</title>
		<link>https://ayalytical.com/product/micro-z-ulsd-analyzer/</link>
		
		<dc:creator><![CDATA[Juan Ayala]]></dc:creator>
		<pubDate>Tue, 02 Jan 2024 12:40:08 +0000</pubDate>
				<guid isPermaLink="false"></guid>

					<description><![CDATA[<p><b>High-precision analyzer for ultra-low sulfur diesel (ULSD).</b></p>
<p><b>Key Features:</b></p>
<ul>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Highly accurate sulfur measurement (in ppm).</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Fast analysis with minimal sample preparation.</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">User-friendly interface with comprehensive software.</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Robust and reliable for continuous operation.</span></li>
<li style="font-weight: 400;" aria-level="2"><span style="font-weight: 400;">Compliant with ASTM and ISO standards.</span></li>
</ul>
<p>The post <a href="https://ayalytical.com/product/micro-z-ulsd-analyzer/">Micro-Z ULSD Analyzer</a> appeared first on <a href="https://ayalytical.com">Ayalytical</a>.</p>
]]></description>
										<content:encoded><![CDATA[<style>.aya-pd{--aya-red:#c8102e;--aya-ink:#1c1c1c;--aya-body:#6f6f6f;--aya-rule:#e2e2e2;color:var(--aya-body);font-size:15px;line-height:1.62;max-width:680px}.aya-pd p{margin:0 0 1.05em;padding:0;color:var(--aya-body)}.aya-pd p:last-child{margin-bottom:0}.aya-pd p:empty{display:none;margin:0}.aya-pd__kicker{margin:0 0 1.4em;font-size:12px;font-weight:600;letter-spacing:.09em;text-transform:uppercase;color:var(--aya-red)}.aya-pd__kicker span{color:var(--aya-body);margin:0 .35em}.aya-pd .aya-pd__display{margin:0;font-size:33px;line-height:1.18;font-weight:700;letter-spacing:-.01em;padding:0}.aya-pd .aya-pd__display--sm{font-size:30px}.aya-pd__h2{margin:0 0 1.4em;font-size:21px;line-height:1.32;font-weight:700;color:var(--aya-ink)}.aya-pd__h3{margin:0 0 .9em;font-size:18px;font-weight:700;color:var(--aya-ink)}.aya-pd__hero{display:flex;flex-wrap:wrap;align-items:center;gap:24px;margin-bottom:56px}.aya-pd__heroText{flex:1 1 260px;padding:0}.aya-pd__heroText .aya-pd__kicker{margin-bottom:1.1em}.aya-pd__herometa{margin:1.2em 0 0;font-size:14px;line-height:1.5}.aya-pd__block{margin-bottom:40px}.aya-pd__block--gap{margin-top:56px}.aya-pd__block .aya-pd__display{margin-bottom:.95em}.aya-pd__divider{height:0;margin:0 0 40px;border:0;border-top:2px solid var(--aya-red);background:none}.aya-pd ul.aya-pd__apps{list-style:none;display:grid;grid-template-columns:repeat(auto-fit,minmax(230px,1fr));gap:22px 28px;margin:0;padding:0}.aya-pd ul.aya-pd__apps li{position:relative;list-style:none;padding-left:22px;font-size:15px;font-weight:600;line-height:1.4;color:var(--aya-ink)}.aya-pd ul.aya-pd__apps li::marker{content:""}.aya-pd ul.aya-pd__apps li::before{content:"";position:absolute;left:0;top:.45em;width:9px;height:9px;border-radius:50%;background:var(--aya-red)}.aya-pd ol.aya-pd__params{list-style:none;margin:0;padding:0}.aya-pd ol.aya-pd__params li{display:flex;list-style:none;gap:24px;padding:22px 0;border-bottom:1px solid var(--aya-rule)}.aya-pd ol.aya-pd__params li::marker{content:""}.aya-pd ol.aya-pd__params li:first-child{border-top:1px solid var(--aya-rule)}.aya-pd ol.aya-pd__params li:last-child{border-bottom:0;padding-bottom:0}.aya-pd__params .aya-pd__num{flex:0 0 auto;font-size:15px;font-weight:700;line-height:1.5;color:var(--aya-red)}.aya-pd__params h4{margin:0 0 .35em;font-size:17px;font-weight:700;color:var(--aya-ink);transition:color .18s ease}.aya-pd__params li:hover h4{color:var(--aya-red)}.aya-pd__params p{margin:0;font-size:14.5px}.aya-pd__footer{display:flex;flex-wrap:wrap;align-items:center;justify-content:space-between;gap:24px 40px;margin-top:34px;padding-top:26px;border-top:2px solid var(--aya-red)}.aya-pd__warranty{flex:1 1 240px}.aya-pd__warranty p{font-size:13.5px;line-height:1.55;margin:0}.aya-pd__cta{flex:0 1 230px;text-align:center}.aya-pd__cta p{margin:0}.aya-pd a.aya-pd__btn{display:inline-block;padding:12px 26px;background:#000;border:1px solid #000;border-radius:0;color:#fff;font-size:13px;font-weight:700;letter-spacing:.08em;line-height:1.2;text-transform:uppercase;text-decoration:none;white-space:nowrap;margin:0;transition:background .2s ease,color .2s ease}.aya-pd a.aya-pd__btn:hover,.aya-pd a.aya-pd__btn:focus{background:#fff;border-color:#000;color:#000;text-decoration:none}.aya-pd :focus-visible{outline:2px solid var(--aya-red);outline-offset:3px}@media (prefers-reduced-motion:reduce){.aya-pd *{transition:none!important}}</style>
<div class="aya-pd">
<section class="aya-pd__hero">
<div class="aya-pd__heroText">
<p class="aya-pd__kicker">Rigaku Micro-Z ULSD <span>/</span> Sulfur analyzer</p>
<h3 class="aya-pd__display"><span class="aya-pd__grad" style="display:inline-block;color:#c8102e;background-color:transparent !important;background-image:linear-gradient(100deg,#3fa3b8 0%,#8c8c8c 48%,#d92b3f 100%) !important;-webkit-background-clip:text !important;background-clip:text !important;-webkit-text-fill-color:transparent !important;">Ultra-low sulfur.<br />Real-world precision.</span></h3>
<p class="aya-pd__herometa">Lower limit of detection: 0.3 ppm S<br />Compliant with ASTM D2622-10, ISO 20884, and JIS K2541-7</p>
</div>
</section>
<h3 class="aya-pd__h2">A novel design for ultra-low level sulfur analysis</h3>
<p>Designed for ultra-low level sulfur analysis of diesel, petrol (gasoline), and other fuels, the Rigaku Micro-Z ULSD sulfur analyzer and wavelength dispersive X-ray fluorescence (WDXRF) instrument features a novel design that measures both the sulfur peak and the background intensity.</p>
<section class="aya-pd__block aya-pd__block--gap">
<p class="aya-pd__kicker">Background correction</p>
<h3 class="aya-pd__display aya-pd__display--sm"><span class="aya-pd__grad" style="display:inline-block;color:#c8102e;background-color:transparent !important;background-image:linear-gradient(100deg,#3fa3b8 0%,#8c8c8c 48%,#d92b3f 100%) !important;-webkit-background-clip:text !important;background-clip:text !important;-webkit-text-fill-color:transparent !important;">Measure the sulfur peak.<br />Correct the background.</span></h3>
<p style="color:#1c1c1c;font-size:16px;">A better net peak intensity measurement, from a single design decision.</p>
<p>The sulfur analyzer&#8217;s ability to measure and correct for changes in background intensity delivers superior calibrations and enhanced real-world precision.</p>
</section>
<hr class="aya-pd__divider">
<section class="aya-pd__block">
<h4 class="aya-pd__h3">Lower limit of detection.</h4>
<p>With a lower limit of detection (LLD) of 0.3 ppm S, the Rigaku Micro-Z ULSD sulfur analyzer complies with ASTM 2622-10, ISO 20884, and JIS K2541-7 methods.</p>
<h4 class="aya-pd__h3">Designed for</h4>
<ul class="aya-pd__apps">
<li>Diesel</li>
<li>Petrol (gasoline)</li>
<li>Other fuels</li>
</ul>
</section>
<section class="aya-pd__block aya-pd__block--gap">
<p class="aya-pd__kicker">Precision <span>+</span> Range</p>
<h3 class="aya-pd__display aya-pd__display--sm"><span class="aya-pd__grad" style="display:inline-block;color:#c8102e;background-color:transparent !important;background-image:linear-gradient(100deg,#3fa3b8 0%,#8c8c8c 48%,#d92b3f 100%) !important;-webkit-background-clip:text !important;background-clip:text !important;-webkit-text-fill-color:transparent !important;">Fixed optics.<br />Switchable focus.</span></h3>
<p>A 40 kV chromium-anode X-ray tube excites the sample at up to 40 W, read by a doubly curved RX-9 analyzing crystal and sealed proportional counter. Fixed optics with a switchable receiving slit select between peak and background, with samples analyzed in air while the optics themselves run under vacuum from an external pump. The analyzer uses a single measurement position with a standard 35 mm cup, keeping running and consumable costs low.</p>
</section>
<hr class="aya-pd__divider">
<section class="aya-pd__block">
<h4 class="aya-pd__h3">Built for non-technical operators.</h4>
<p>Every step from calibration to routine analysis runs through the same on-board interface, powered by any standard wall AC outlet.</p>
<h4 class="aya-pd__h3">At a glance</h4>
<ul class="aya-pd__apps">
<li>LCD display + membrane keypad</li>
<li>Up to 10 calibrations, 30 standards each</li>
<li>Selectable analysis time, up to 900 s</li>
<li>Optional thermal dot printer</li>
</ul>
</section>
<section class="aya-pd__block aya-pd__block--gap">
<p class="aya-pd__kicker">Description highlights</p>
<h3 class="aya-pd__display aya-pd__display--sm"><span class="aya-pd__grad" style="display:inline-block;color:#c8102e;background-color:transparent !important;background-image:linear-gradient(100deg,#3fa3b8 0%,#8c8c8c 48%,#d92b3f 100%) !important;-webkit-background-clip:text !important;background-clip:text !important;-webkit-text-fill-color:transparent !important;">Superior calibrations.<br />Enhanced real-world precision.</span></h3>
<ol class="aya-pd__params">
<li><span class="aya-pd__num">01</span>
<div>
<h4>Measurement Design</h4>
<p>Measures both the sulfur peak and the background intensity.</p>
</div>
</li>
<li><span class="aya-pd__num">02</span>
<div>
<h4>Lower Limit of Detection</h4>
<p>0.3 ppm S.</p>
</div>
</li>
<li><span class="aya-pd__num">03</span>
<div>
<h4>Methods</h4>
<p>ASTM 2622-10, ISO 20884, and JIS K2541-7.</p>
</div>
</li>
</ol>
</section>
<section class="aya-pd__footer">
<div class="aya-pd__warranty">
<h4 class="aya-pd__h3">WDXRF</h4>
<p>Wavelength dispersive X-ray fluorescence (WDXRF).</p>
</div>
<div class="aya-pd__cta"><a class="aya-pd__btn" href="https://ayalytical.com/contact-us/?product_id=42276">Request a Quote</a></div>
</section>
</div>
<p>The post <a href="https://ayalytical.com/product/micro-z-ulsd-analyzer/">Micro-Z ULSD Analyzer</a> appeared first on <a href="https://ayalytical.com">Ayalytical</a>.</p>