Automatic Potentiometric Titrator AT-710 Series
Advanced titrator for precise and automated acid and base number analysis.
Key Features:
-
- High precision in titration with automated controls.
- User-friendly interface with easy data management.
- Suitable for various titration methods and applications.
- Durable design for consistent performance.
- Compliant with ISO and ASTM standards.
ASTM, D664
The Automatic Potentiometric Titrator AT-710 Series is fully compliant with ASTM D664. The AT-710M has a unique flexibility with up to 4 simultaneous titrations of any type.
The AT-710M as a flagship model comes with the largest titration user interface available in the market. The main control unit of this model, MCU-710M, provides a unique user experience with its 8.4 inch LCD touch panel and can be the common basis for up to four full-fledged titrators of any type, being the MKV-710B Volumetric or MKC-710B Coulometric Karl Fischer moisture titrators or additional AT-710B potentiometric titrators. This saves space and avoids tangled cables. The connections between the main control unit and the potentiometric titrators can be setup wireless, while the main control unit can be connected to a PC with a LAN cable.
The wireless bluetooth communication offers substantial benefits in terms of safety and space requirements. The operation is easier and safer when toxic samples have to be measured as the main control unit can be located outside of its hood.
TheAutomatic Potentiometric Titrator AT-710 is convenient and has a easy to follow navigator for its calibration.
See the full specs and downloadable brochure for more details.
Features
Display colors can be changed
Models
Models | Titration mode |
Automatic Potentiometric Titrator [AT-710M] | Auto Titration, Auto Intermit, Intermit, Stat, Petroleum Titration, COD |
Automatic Potentiometric Titrator [AT-710S] | Auto Titration, Auto Intermit, Intermit, Stat, Petroleum Titration, COD |
Automatic Potentiometric Titrator [AT-710B] | Auto Titration, Auto Intermit, Intermit, Stat |
Accessories
The following accessories are recommended for purchase in sequential order (see eStore):
1st Year: | No spare parts are required |
2nd Year: | No spare parts are required |
Remaining Parts: |
Specs
Test standards | ASTM D664 | |
Type | Automatic Potentiometric Titrator | |
Product configuration | AT-710 + IDP-100 + Propeller stirrer | |
Detection range | 1) Potentiometric : -2000mV to +2000mV 2) pH : -20.000 to 20.000pH 3) Temp. : 0 to 100°C |
|
Titration mode | Auto Titration , Auto Intermit , Intermit , Stat | |
Method | 20 (Max 2 methods can be linked) | |
Kinds of titration | Potentiometric (acid/base , redox , precipitation) , Photometric , Polarization , Conductivity | |
Titration form | Full titration (Auto EP detection) , EP Stop , Level Stop | |
Special application | Measurement of electrode potential (pH , potential) , Acid dissociation constant (pKa | |
Key operation | Sheet key | |
Displays | 1) White LED-backlit LCD 2) English / Japanese / Mandarin Chinese / Korean / Russian / Spanish 3) 1-channel display |
|
Calculation | Concentration of content , statistics data processing (mean , SD and RSD) and automatic averaging of blank and factor value | |
Data storage | 50 samples | |
GLP conformance | Registration of operator / Record of check results / Record of electrode calibration / Verification of burette capacity / Management of conduction time | |
Burette size | 20mL glass burette with brown cover (Standard) Optional burette units : 10mL , 5mL , or 1mL |
|
Burette accuracy | 50mL burette(Auto dispenser) +/- 0.5mL 20mL burette +/- 0.02mL ; reproducibility +/- 0.01mL 10mL burette +/- 0.015mL ; reproducibility +/- 0.005mL 5mL burette +/- 0.01mL ; reproducibility +/- 0.003mL 1mL burette +/- 0.005mL ; reproducibility +/- 0.001mL |
|
Preamplifier | 1) STD : pH (mV) and mV, 2 inputs (Standard) 2) PTA : pH (mV) , mV and photometric, 3 inputs 3) POT : pH (mV) , mV and polar, 3 inputs 4) CMT : pH (mV) , mV and conductivity, 3 inputs (factory setting required) 5) TET : pH (mV) 2 ways and mV , inputs (factory setting required) |
|
External I/O | RS-232C : for Dot matrix printer/Electronic balance/Data Capture Software (SOFT-CAP) port x2 SS-BUS x1 : for Multiple sample changer , APB ELE. x1 : for Smart electrode USB x1 : for USB flash drive, Thermal printer, Keyboard, Barcode reader, Foot switch, USB HUB TEMP.COMP. x1 : Input terminal for temperature sensor to correct reagent volume, sensor Pt100, temperature reading accuracy : +/- 0.5°C (burette 1 only) |
|
Extensibility | Automatic piston burette : Can control max 10 burette drives (Including two built-in burette drives) Multiple sample changer : CHA-700 |
|
Ambient condition | 1) Temperature : 5 to 35°C 2) Humidity : 85%RH or below (no condensation) |
|
Conformity standard | CE marking EMC : EN61326-1 LVD : EN61010-1 RE Directive Burette unit EBU FCC Part15 SubpartC FCC ID : 2ABSVEBU01 |
|
Option | Printer – Thermal Printer, Dot Matrix Printer Sampling Unit, Changer – DCU-551N, CHD-502N Software – SOFT-CAP (Data acquisition software) |
|
Power source | AC100 to 240V +/- 10% 50/60 Hz | |
Power consumption | Main unit : Approx. 20W Printer : Approx. 7W |
|
Weight | Titration unit : Approx. 4.0kg Printer : Approx. 0.4kg |
|
Dimensions | Titration unit : 141(W) x 296(D) x 367(H)mm (not incl. tubing) Printer : 106(W) x 180(D) x 88(H) mm |