Automated Tag Closed Cup Flash Point Tester
Precision instrument for measuring the closed cup flash point.
Key Features:
- High accuracy in flash point detection.
- User-friendly operation with automated features.
- Durable construction for reliable performance.
- Comprehensive data logging capabilities.
- Compliant with ASTM and ISO standards.
ASTM, D56, ISO, 2719
Features

TN 6000 is fully compliant with ASTM D4629, ASTM D5762, ASTM D6069, providing both standard method and refined methodology.

TN 6000 is fully compliant with ASTM D4629, ASTM D5762, ASTM D6069, providing both standard method and refined methodology.

TN 6000 is fully compliant with ASTM D4629, ASTM D5762, ASTM D6069, providing both standard method and refined methodology.

TN 6000 is fully compliant with ASTM D4629, ASTM D5762, ASTM D6069, providing both standard method and refined methodology.

TN 6000 is fully compliant with ASTM D4629, ASTM D5762, ASTM D6069, providing both standard method and refined methodology.
Accessories
The following accessories are recommended for purchase in sequential order (see eStore):
1st Year: | Thermofuse (pack of 5) Electric igniter Temperature sensor Flash detector Printer paper |
2nd Year: | Test cup assembly |
Remaining Parts:/td> |
Specs
Test standards | ASTM D56, IP 304 | |
Type | All in one microprocessor controlled | |
Measuring range | Ambient to 95 | |
Temperature sensor | PT-100 in stainless steel sheath | |
Measurements Modes | ASTM CRM, ASTM Normal, ASTM SPE (search), ASTM Rapid and User custom | |
Display | 5.7 inch (117 x 88mm) color LCD with LED back ligh | |
Heater | Band type heater:530W at 115V or 500W at 230V | |
Cooling device | Forced air cooling by fan | |
Stirring | 100, 250 rpm (selectable) | |
Flash detector | CRC Thermocouple | |
Ignition source | Gas ignition with automatic lighting or electric ignition. Interchangeable | |
Barometric correction | Automatic correction by built-in barometric pressure sensor | |
I/O port | RS-232C = 1 channel (for PC or Optional Printer) USB=1 channel (for USB keyboard or USB Flash Memory) | |
Gas supply (When gas ignition is used) |
LP gas or natural gas (Max. pressure:10kPa) | |
Safety shutdown | Automatically shuts off and the problem is reported by buzzer and display, in case: (a) EFP+10°C or 95°C is reached, (b) temperature sensor is found defective, (c) flash detector is found defective, (d) thermofuse is blown, (e) electric Igniter is blown, (f) built-in battery is found drained out, (g) test cover is not set in place, (h)control computer runs away (no display) (i) Stirring motor stopped |
|
Electricity consumption | 40Wh for 1 test (about 30 min), 15.12gCO2 (at 0.378kg CO2/1kWh) | |
Power consumption | 720W max | |
Power supply | 100/120VAC or 220/240 VAC, 50/60Hz | |
Weight | 17 kg (37 lbs) | |
Dimension | 23x47x39 cm (9x18x15 inches) |