Fully compliant with ASTM D3120, ASTM D5194, ASTM D5808, ASTM D4929, the TSHR TX 1800 Total Chlorine Analyzer is an analyzer designed for the measurement of organic halides in a wide range of liquid and solid matrices, with respect to international standards. Exceptional accuracy and precision is reached by using temperature controlled furnaces and a turbo combustion quartz tube for conditioning of the combustion gases.
The TX 1800 chlorine residual analyzer is a compact and robust system for laboratories with an average number of total chlorine analysis. The instrument saves bench space and reduces investment costs without biasing the quality or reliability of microcoulometric sub ppm analysis. The total chlorine analyzers special design gives easy and safe access to all serviceable parts, while requiring minimum maintenance.
The sample is introduced in an heated oxygen free zone where the sample is vaporized, after the vaporization the gases flow into the combustion area where the sample will be oxidized in a controlled two-staged furnace. After the combustion, the gases go through a conditioning step where all moisture and other interferences are removed. The clean combustion gas will flow towards the coulometric cell where the halide ions react with the present silver ions. The amount of charge needed to regenerate the precipitated silver ions is directly related to the Halide concentration.
View Specs tab for a full range of TX 1800 total chlorine analyzer features.
Features
Accessories
The following accessories are recommended for purchase in sequential order (see eStore):
1st Year: | No spare parts are required |
2nd Year: | No spare parts are required |
Remaining Parts: | Gas Injection Module |
Specs
Specific compliant methods | ASTM D4929, D5194, D5808, D3120 UOP 779 | |
TX liquids | 0.1 – 5000 mg/kg | |
Liquids | 1 – 100 μL | |
Analysis time | < 10 minutes | |
Relative standard deviation | < 5% | |
Sample matrix | High and low boiling liquids up to 450 °C (842 °F) | |
Furnace Voltage | 2 x 24 V, 50/60 Hz | |
Furnace Power | 2 x 300 W | |
Furnace Temperature Sensor | 2 x Ni-Cr/Ni | |
Furnace configuration | Dual temperature controlled | |
Furnace Temperature | 1250 °C Max | |
Type of Analyses | Total Halogens and Total Sulphur | |
Detection Principle | Micro Coulometric Titration | |
PC operating system | Windows 7 or higher | |
Computer | Intel Core i3 / AMD Phenom or better | |
Software | Athena | |
Optional accessories | Gas Injection Module | |
Ambient temperature | 5 – 35 °C (41 – 95 °F) | |
Gas pressure | 2 – 3 Bar (30-45 psi) | |
Gas connector | 1/8” swagelok | |
Voltage | 115/230 V, 50/60 Hz | |
Power | 1200W | |
Weight | ||
Dimensions | ||
Shipping weight | ||
Dimension with crate |
Videos
Downloads
Download our brochure for more details
Tags
eStore
You May Also Like
-
Cathode, Pt
$303.46 -
Cathode, Pt, Cap. cell
$303.44 -
Clamp with screw no:12
$39.30 -
Connection furnace/scrubber 1200/1600
$858.00 -
Electrode container capillary cell
$127.18 -
Electrode container, 35ml cell
$127.18 -
Gasinlet
$85.68 -
Generating electrode, Ag, cap. cell
$303.46 -
Generating electrode, Pt, 35ml cell
$303.46 -
Glas connector extra outlet 1/4"
$67.84 -
Halogen reference electrode, Ag/AgCl
$331.02 -
Halogens scrubber
$401.62 -
Halogens titration cell, capillary
$1,517.26 -
Injection needle Hamilton, 71mm, p.s. 5, 3 pcs
$213.20 -
Measuring electrode, Ag, cap. cell
$303.46 -
Measuring electrode, Pt, 35ml cell
$303.46 -
NOX scrubber
$232.06 -
Quartz frit (3pcs)
$303.46 -
Quartz sample cup, solids
$80.32 -
Scrubber model 1800
$718.00 -
Septum, diam. 12mm, 10 pieces
$35.50 -
Splashbulb
$139.70 -
Stirrer Bar
$20.78 -
Sulfur cell iodometric, 35ml
$1,588.66 -
Sulfur reference electrode, Pt
$303.46 -
Turbo combustion tube
$1,218.00