by Oscar | May 22, 2025 | News, Whitepaper
ERAFLASH X: The Future-Proof Replacement for ASTM D93 Pensky-Martens Testers The field of flash point testing has seen significant advancements with the introduction of the ERAFLASH X by Eralytics. This cutting-edge device is on track to replace the traditional ASTM...
by Juan Ayala | Jan 2, 2024
Jet fuel module (correlation to ASTM D86, D93, D445, D1322, D2386, D2425, D4052) Absorption cell (100 m) and software package for a comprehensive Jet fuel analysis in combination with ES01 ERASPEC FTIR analyzer base unit. The Jet fuel module allows for the direct...
by Cristina Ayala | Feb 13, 2020
ASTM D93 Flash Point by Pensky-Martens Closed Cup Tester ASTM D93 stands for standard test methods for Flash Point by Pensky-Martens Closed Cup Tester. In these cases, a manual Pensky-Martens closed-cup apparatus or an automated Pensky-Martens closed-cup apparatus are...
by Crystal Heetai | Nov 25, 2024
Ayalytical Instruments supplies Anisole and n-Decane in one-liter bottles, which are primarily used for flash point certified reference material. The one-liter bottles contain Anisole 99.7% in accordance with ASTM methods D6450 and D7094, as well as n-Decane ? 99% in...
by Juan Ayala | Jan 8, 2024
ASTM standard tests methods ASTM role in production and trade of product and services International trade of crude oils and products requires a marketplace based on fair economic competition without unreasonable restraints and operating in an open and transparent...
by Juan Ayala | Jan 6, 2024
OIL CONDITION MONITORING Oil Condition Monitoring ERALAB OCM Fast & easy wear metal and contamination analysis. Oil Condition Monitoring plays a crucial role in predictive and proactive maintenance strategies by providing valuable insights into equipment health...
by Juan Ayala | Jan 2, 2024
Ayalytical Instruments supplies Anisole and n-Decane in one-liter bottles, which are primarily used for flash point certified reference material. The one-liter bottles contain Anisole 99.7% in accordance with ASTM methods D6450 and D7094, as well as n-Decane ? 99% in...
by Juan Ayala | Jan 2, 2024
The innovative designs of the various Pensky-Martens Flash Point apparatuses guarantee compliancewith ASTM D93, ASTM E502, DIN 51 758, EN 22719, IP 34, ISO 2719, and ISO 15267, for determining thelowest temperature at which sample vapors ignite when a gas or electric...
by Juan Ayala | Jan 2, 2024
Pinpoint accuracy, for when precision is critical The versatile capabilities of Ayalytical Instruments precision cone penetrometer ensures full compliance with ASTM D5, ASTM D2178, ASTM D937, ASTM D1321, ASTM 1403, ASTM D2884, DIN 51 579, DIN 51 580, EN 1426, IP 49,...
by Juan Ayala | Dec 8, 2020
ASTM D6468-19 Standard Test Method for High Temperature Stability of Middle Distillate Fuels Standard test method ASTM D6468 covers relative stability of middle distillate fuels under high temperature aging conditions with limited air exposure. This test method is...
by Juan Ayala | Jun 8, 2020
49 CFR Parts 106, 107, 171-180 DOT Flash Point _ 40 CFR Part 260, 261 and 266 Methods: ASTM D93, ASTM D6450, ASTM D7094 Modernizing Ignitable Hazardous Liquids Determinations Flash Point by definition is the lowest temperature at which vapors of a volatile material...