Capillary Viscometers | Glass Capillary Viscometers

Methods:
ASTM, D445, D446, D2170, IP, 71, ISO, 3105, 3104

Login or Register to buy or

[request_quote_button]

Ayalytical Instruments offers a full range of 14 glass capillary viscometers for compliance with ASTM D445, ASTM D446, ASTM D2170, IP 71, ISO 3104, and ISO 3105 testing requirements for measuring kinematic viscosities of transparent Newtonian liquids. Calibrated glass capillary viscometers include a certificate of calibration.

The following designs of glass capillary viscometers are available for your viscosity measuring needs:

Ubbelohde Viscometer: For transparent Newtonian liquids in accordance with ASTM D445, ASTMD446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 11 mL in a liquid bathof 241 mm. Available in 16 models, for varying viscosity ranges. Also available in uncalibrated model,upon request.

Cannon-Fenske Routine Viscometer: For transparent Newtonian liquids in accordance with ASTM D445, ASTM D446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 7 mL in a liquid bath of 203 mm. Available in 13 models, for varying viscosity ranges. These glass capillary viscometers are also available in uncalibrated model, upon request.

Cannon-Fenske Opaque Viscometer: For opaque Newtonian liquids in accordance with ASTM D445,ASTM D446, ASTM D2170, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of12 mL in a liquid bath of 229 mm. Available in 14 models, for varying viscosity ranges. Also available inuncalibrated model, upon request.

BS/IP/MSL Miniature Suspended Level: For transparent Newtonian liquids in accordance with ASTMD445, ASTM D446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 4 mL in aliquid bath of 305 mm. Available in 7 models, for varying viscosity ranges.

BS/IP/SL Suspended Level: For transparent Newtonian liquids in accordance with ASTM D445, ASTM D446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 11 mL in a liquid bath of 250 mm. These glass capillary viscometers are available in 9 models, for varying viscosity ranges.

BS/U/M Miniature U-tube: For transparent Newtonian liquids in accordance with ASTM D445, ASTMD446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 2 mL in a liquid bathof 230 mm. Available in 5 models, for varying viscosity ranges.

BS/U Tube: For transparent Newtonian liquids in accordance with ASTM D445, ASTM D446, IP 71, ISO3104, and ISO 3105 requirements. Requires minimum sample of 7-23 mL in a liquid bath of 280 mm.Available in 8 models, for varying viscosity ranges.

Cannon-Manning Semi-Micro: For transparent Newtonian liquids in accordance with ASTM D445,ASTM D446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 1 mL in a liquidbath of 200 mm. Available in 12 models, for varying viscosity ranges. Also available in uncalibratedmodel, upon request.

DS/IP/SL (S) Suspended Level: For transparent Newtonian liquids in accordance with ASTM D445,ASTM D446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 11 mL in aliquid bath of 250 mm. Available in 9 models, for varying viscosity ranges.

Cannon-Ubbelohde Dilution: For transparent Newtonian liquids in accordance with ASTM D445, ASTMD446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 8 mL (can be dilutedto 40 mL) in a liquid bath of 305 mm. Available in 12 models, for varying viscosity ranges. Also availablein uncalibrated model, upon request.

Cannon- Ubbelohde Semi-Micro: For transparent Newtonian liquids in accordance with ASTM D445,ASTM D446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 1 mL in a liquidbath of 240 mm. Available in 12 models, for varying viscosity ranges. Also available in uncalibratedmodel, upon request.

BS/IP/RF U-tube A Scalomento Rovesciato: For opaque Newtonian liquids in accordance with ASTMD445, ASTM D446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 7 mL in aliquid bath of 280 mm. Available in 11 models, for varying viscosity ranges.

Zeitfuchs Cross-Arm: For both transparent and opaque Newtonian liquids in accordance with ASTMD445, ASTM D446, ASTM D2170, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimumsample of 1-3 mL in a liquid bath of 230 mm. Available in 10 models, for varying viscosity ranges.

Zeitfuchs Transparent: These glass capillary viscometers are for transparent Newtonian liquids in accordance with ASTM D445, ASTM D446, IP 71, ISO 3104, and ISO 3105 requirements. Requires minimum sample of 15 mL in a liquid bath of 292 mm. Available in 7 models, for varying viscosity ranges. Also available in uncalibrated model, upon request.

AYALYTICAL EXCLUSIVE SERVICES

ISO OEM 17025 Certified

Our Service Center has been ISO Accredited for Competence of Calibration.

AYALYTICAL EXCLUSIVE SERVICES  

1-3 Days Service Turn Around

 

We are please to offer our 1-3-day service turn around from our Ayalytical Service department.

AYALYTICAL EXCLUSIVE SERVICES

Application Support

 

We are pleased to offer our expertise in various disciplines including Physical Properties, Elemental and Compositional.

AYALYTICAL EXCLUSIVE SERVICES

Dedicated Support Lines

 

We are pleased to offer our On-Site trainings and service calls for our Ayalytical partners.