Density/Specific Gravity Meter
Compact density meter for precise measurement of liquid densities.
Key Features:
- High-resolution digital display for easy readings.
- Fast and accurate density measurements.
- Compact and portable design for lab or field use.
- User-friendly interface with simple calibration.
- Compliant with ISO standards for density measurement.
ASTM, D4052, D1475, D5798, D1250, D4806, D5002, D5931, ISO, 12185, 15212
Just imagine the model where a weight is attached to a bar at the end and a bar is fixed on a wall as shown in the right figures. And when you hit the weight by a finger, the weight starts vibrating. Now you will find that the heavier the weight becomes, the slower it vibrates, and vice versa. This is because the weight will vibrate on the oscillation period specific to a substance in proportion to the mass of weight. This means that one can determine the density of a substance by measuring its oscillation period since density becomes proportional to the mass when the volume is constant, i.e. a fixed tube. Contact us with any questions about this electronic density/specific gravity meter.
Features
Density/Specific Gravity Meter is fully compliant with ASTM D1250, ASTM D1475, ASTM D4052, ASTM D4806, ASTM D5002, ASTM D5798, ASTM D5931, providing both standard method and refined methodology.
Accessories
The following accessories are recommended for purchase in sequential order (see eStore):
1st Year: | Filter Silica Gel (500g) Syringe 2mL x 2 Thermal Roll Paper P-58-30 (10 rolls)For Thermal Printer Thermal Roll Paper STH-215 (10 rolls)For Thermal Printer Printing Roll RP5860 4rolls Set For Dot Matrix Printer Ribbon Cartridge IR-91B Black (5pcs/set For Dot Matrix Printer |
2nd Year: | No spare parts are required |
Remaining Parts: |
Specs
Test standards | ASTM D1250, D1475, D4052, D4806, D5002, D5798, D5931, ISO 12185, ISO 15212 | |
Measuring method | Resonant frequency oscillation | |
Measurement Range | 0 ~ 3 g/cm3 | |
Temperature Range | 0 ~ 96°C (32 ~ 204.8°F) | |
Accuracy | Density: Models DA-650 DA-650B: ±2×10-5 g/cm3 (0.00002 g/cm3) Models DA-645 DA-645B: ±5×10-5 g/cm3 (0.00005 g/cm3) Models DA-640 DA-640B: ±1×10-4 g/cm3 (0.0001 g/cm3) (Calibration with air and water required.) Temp: Models DA-650 DA-650B: ±0.02 °C (±0.04 °F) Models DA-645 DA-645B: ±0.03 °C (±0.05 °F) Models DA-640 DA-640B: ±0.05 °C (±0.09 °F) |
|
Repeatability*2 | Density SD 5×10-6 g/cm3, SD 1×10-5 g/cm3, SD 5×10-5 g/cm3 | |
Minimum Sample Required | 1) Approx. 1 mL (Syringe) 2) Approx. 2 mL (Pump) |
|
Measurement Time | 1) 1 to 4 mins (Manual) 2) 2 to 10 mins (Auto) |
|
Display | 1) 5.7-inch colour TFT LCD; 640 x 480 2) Shows density, specific gravity, oscillation frequency, temperature, concentration and other messages |
|
Resolution | Density & Specific Gravity: 0.000001 Temperature: 0.001 |
|
Auto calibration | Density of water at each temperature, required for calibration of measuring cell, is pre-installed. | |
Sampling by | Syringe-type hand pump | |
Viscosity Correction | Models DA-650 – Yes DA-650B – No DA-645 D – Yes A-645B – No DA-640 – Yes DA-640B – No |
|
Sampling | 1) Manual by syringe 2) Auto by sampling pump*3 |
|
Method | Saves up to 100 different methods in built-in memory | |
Stability | Four modes of stability according to measurement accuracy and time | |
Density Auto Correction | 1) Saves conversion table or formula at your desired temperatures according to your samples. 2) Temperature conversion table preprogrammed according to ASTM standard for petroleum, petroleum products and lubricating oils |
|
Auto Conversion | 1) Between concentration and density 2) Between temperature and density |
|
Statistics | 1) Auto or manual calculation of mean value, SD and coefficient 2) Recalculation, data deletion |
|
Interfaces | 1) LAN: x 1; Personal computer (PC) 2) USB 1.1: x 2; USB flash drive, keyboard, barcode reader, Epson inkjet printer *4 3) Software: x 2; Dot Matrix Printer, Auto Clean and Sampling Unit, Multiple Sample Changer |
|
Options | 1) Printer: Thermal Printer, Dot Matrix Printer 2) Sampling Unit, Changer: DCU-551N/H, CHD-502N/H/C 3) Software: SOFT-CAP (Data Acquisition Software) |
|
Data I/O | 1) USB flash drive as data storage medium 2) Application Notes provided in USB flash drive |
|
Wetted Materials | PTFE, borosilicate glass, SUS304 | |
Ambient Conditions | 1) Temperature: 5 ~ 35 °C (41 ~ 95 °F) 2) Humidity: 85%RH or below (No condensation allowed.) |
|
Power Supply | AC 100 ~ 240V; 50/60Hz (Comes with AC adapter.) | |
Power Consumption | 40W (max. 120W, min. 20W) | |
Dimensions | 320 (W) x 365 (D) x 250 (H) mm (12.6 (W) x 14.4 (D) x 9.8 (H) inches) | |
Weight | 18 kg (39.7 lbs) | |
Export Packing in Double Carton Box | G/W 21 kg (46.3 lbs); 540 (W) 480 (D) 460 (H) mm (21.3 (W) 18.9 (D) 18.1 (H) inches) (May vary in some cases.) |
Downloads
Download our brochure for more details