OXIDATION STABILITY – MINERAL INSULATING OIL

Methods:
ASTM, D665, D2440, EN, 61125-A, 61125-B, 61125-C, IP, 48, 280, 306, 307, 335, ISO, 7624

Login or Register to buy or

[request_quote_button]

The oil oxidation test apparatus has a 6-positions oil bath with a double bottom. The oxidation stability apparatus also has a stainless-steel structure with insulation double wall, cover with 6 holes as well as support for the flowmeters and absorption tubes. Temperature regulation for the oxidation stability test is controlled by a digital thermoregulator PID with PT100 probe class A and overtemperature alarm, stainless steel heater, motor stirrer, safety internal level for low liquid with warning lamp, drain cock.Purchase this oxidation stability apparatus online.

Features

features__astm compliant OXIDATION STABILITY – MINERAL INSULATING OIL fully compliant with ASTM D2440, providing both standard method and refined methodology.

Models

Models    Positions
Model 1980   OXIDATION STABILITY 
Model 1980/S/4   OXIDATION STABILITY DRY BATH (4 POSITIONS)
Model 1980/S/8   OXIDATION STABILITY DRY BATH (8 POSITIONS)

Accessoires

The following accessories are recommended for purchase in sequential order (see eStore):

1st Year: COPPER CATALYST, pack of 5 pcs x4
SILICON CARBIDE ABRASIVE CLOTH 100 GRIT, pack of 25 m x2
SILICON CARBIDE ABRASIVE CLOTH 220 GRIT, pack of 25 m x2
2nd Year: Same as 1st year
Remaining Parts: OXIDATION/ABSORPTION TUBE
DRECHSEL HEAD With inlet tube
PROBE PT100A
HEATER (for oil bath)
HEATER (for dry bath)
DIGITAL THERMOREGULATOR
STATIC RELAY
BIPOLAR GREEN SWITCH
BIPOLAR YELLOW SWITCH
MOTOR STIRRER
OXIDATION/ABSORPTION TUBE Borosilicate glass Ø26×210 mm with Drechsel head and inlet tube 24/29 ground joint The test mehod “B” and “C” required two oxidation tube
CONNECTION SET For connections the oxidation tube and absorption tube and flowmwter. Consisting of: 3 m silicone tube and 10 glass tubing.
FLOWMWTER 0.6-4 l/h For oxygen at 1 l/h For methods: ASTM D2440, IP 280, IP 306, IP 307, IP 335, EN 61125-A EN 61125-B
FLOWMETER 0.1-1.55 l/h For air at 0.15 l/h For method: EN 61125-C
FLOWMETER 2.5-25 l/h For air at 15 l/h For method: IP 48
SOAP BUBBLE FLOWMETER
Graduated from 0 to 10 ml
REDUCER MANOMETER FOR O2 Cylinder fitting
REDUCER MANOMETER FOR AIR Primary 0-250 bar, reducer 0-1 bar
COPPER CATALYST, pack of 5 pcs L=3 m., (not necessary for IP 48)
SILICON CARBIDE ABRASIVE CLOTH 100 GRIT, pack of 25 m (not necessary for EN 61125)
SILICON CARBIDE ABRASIVE CLOTH 220 GRIT, pack of 25 m (not necessary for EN 61125)
SILICONE OIL 20 cSt pack of 25 kg For temperature from ambient to 120°C (248°F)
SILICONE OIL 50 cSt, pack of 25 kg For temperature from 100°C (212°F) to 200°C (392°F)
PORCELAIN CRUCIBLE, pack of 5 pcs 50 ml
BURETTE 10 ml., div.0.01 ml.
FILTER FUNNEL 125 ml.
ANALYTICAL BALANCE Range 220 g., readout 0.0001, pan Ø80
DIGITAL STOPWATCH 7 digit LCD, max.10 hours, 1/100 sec, digit h=8 mm
THERMOMETER IP22C For method IP 48
THERMOMETER ASTM 9C IP 15C For method IP 280, IP 307, IP 335
THERMOMETER ASTM 40C IP 80C For method IP 307, IP 335, EN 61125-A,
THERMOMETER ASTM 41C IP 81C For method ASTM D2440, IP 280, IP 306, IP 335, EN 61125-B, EN 61125-C

Specs

Test Method Compliance   ASTM D2440 EN 61125-A EN 61125-B EN 61125-C IP 48 IP 280 IP 306 IP 307 IP 335
    OXIDATION STABILITY BATH
Temperature   from ambient to 210°C (410°F)
Stability   ±0.1°C
Power supply   230V ±10% 50/60Hz
Power    2400W
Weight   35 kg
Dimensions   60x57x52 cm
    OXIDATION STABILITY DRY BATH (4 POSITIONS)
Temperature   from ambient to 210°C (410°F)
Stability   ±0.5°C
Power supply   230V ±10% 50/60Hz
    OXIDATION STABILITY DRY BATH (8 POSITIONS)
Temperature   from ambient to 210°C (410°F)
Stability   ±0.5°C
Power supply   230V ±10% 50/60Hz
Power   1900W
Weight   45 kg
Dimensions   45x45x52 cm
Shipping weight    
Dimensions with crate    

 

Downloads

AYALYTICAL EXCLUSIVE SERVICES

ISO OEM 17025 Certified

Our Service Center has been ISO Accredited for Competence of Calibration.

AYALYTICAL EXCLUSIVE SERVICES  

1-3 Days Service Turn Around

 

We are please to offer our 1-3-day service turn around from our Ayalytical Service department.

AYALYTICAL EXCLUSIVE SERVICES

Application Support

 

We are pleased to offer our expertise in various disciplines including Physical Properties, Elemental and Compositional.

AYALYTICAL EXCLUSIVE SERVICES

Dedicated Support Lines

 

We are pleased to offer our On-Site trainings and service calls for our Ayalytical partners.