ERAFLASH LT
Low-temperature flash point tester for various applications with the widest measurement range on the market.
Key Features:
- Accurate measurements down to -15°C (5°F), and with external chiller to -40°C (-40°F)
- Small sample volume required
- Fast and reliable results, user-friendly interface
- Portable and rugged design
- Complies with different standards
ASTM, D92, D56, D3828, D93, D6450, D7094, IP, 34, 170, ISO, 13736, 3679, 2719
A new member among Eralytics flash point testers is the ERAFLASH LT. It is based on the unrivaled performance of ERAFLASH and adds new benefits for fast low-temperature flash point testing.
The stacked Peltier design allows measurements according to ASTM D7094 with oven temperatures as low as -40 C, and the cooling speed of the instrument was increased by approximately 35%. With ERAFLASH LT, simple low-temperature flashpoint testing is possible without the need to cool the equipment with dry ice or other substances.
The ERAFLASH LT flash point tester is also equipped with a coolant valve that automatically shuts the coolant flow off if not needed. This helps to eliminate condensation of humidity on the cooler. Ice formation on the oven surface during the cool-down period is prevented by using a cooling cup that shields the surface from the ambient air.
To request a quote for this Eralytics flash point tester, please click here.
Features
ERAFLASH is fully compliant with ASTM D7094 and ASTM D6450.
All eralytics analyzers use an intuitive menu structure that is easy to navigate. Samples need no prior preparation and measurements are done fully automated.
A direct out-of-the-box connection to LIMS (Laboratory Information Management System) is established with a standard Ethernet cable.No extra software or PC are necessary.
The small footprint of the eralytics instruments makes them the first choice for use in the lab and on-site.
The Eralytics units are all lightweight and built with an integrated carrying handle, they are versatile and ideally suited for mobile applications as well.
All Eralytics analyzer results are displayed immediately after the test on their large and user-friendly color touch screen.
Cleaning after measurements often took time and involved maintenance activities or replacing sensors or other elements of the chamber assembly. The ERAFLASH is different. Its innovative CPT-Contamination Prevention Technology TM, a combination of an advanced electrode protection and self-cleaning ignition system, reduces cleaning & maintenance to an absolute minimum.
The ERAFLASH’s innovative PBT – Peltier Boost Technology TM, a patented eralytics innovation, allows for previously unmatched heating and cooling rates. Paired with the conveniently small size of the sample cup this analyzer allows turnaround times that are significantly shorter than those offered by all other instruments available on the market.Accessories
The following accessories are recommended for purchase in sequential order (see eStore):
| 1st Year: | No spare parts are required |
| 2nd Year: | D7094 Sample cup standard (aluminum, nickel plated, 2 ml) D6450 Sample cup standard (aluminum, nickel plated, 1 ml) Sample cup carrier Stirring magnet Disposable pipettes (5 pcs.) Brass eraser for cleaning of electrodes Cleaning tools for electrodes and oven surface (wet and dry sweeper) (5 pcs.) Ceramic ERAFLASH sample temperature sensor ERAFLASH oven temperature sensor |
| Remaining Parts: |
Specs
| Available Test Methods | ASTM D6450, ASTM D7094 | |
| Pre-Programmed Correlation Methods to | Pensky Martens Closed Cup: ASTM D93, EN ISO 2719, DIN 51758, IP 34, JIS K2265 TAG Closed Cup: ASTM D56 Abel Pensky Closed Cup: ISO 13736, IP 170 Small Scale Closed Cup and Flash / No Flash methods: EN ISO 3679, EN ISO 3680, ASTM D3828 |
|
| Fuel Specifications (ASTM D7094) | ASTM D396, ASTM D975, ASTM D2880, ASTM D3699, ASTM D7467 | |
| Speed Tests | Fast screening test programs for unknown samples | |
| Stacked Peltier Technology | High speed measurements at mid and low temperatures -40 °C to 120 °C (-40 °F to 248 °F) |
|
| CPT – Contamination Prevention Technology | Advanced electrode protection and self-cleaning ignition system to minimize cleaning and maintenance | |
| Combustion Graphics | Display of combustion characteristics for contamination analysis | |
| QuickCal | Dry Block Calibration with eralytics unique directly attached Temperature Calibration Block (EF01-TCB) | |
| Fuel Dilution Program | Automatic fuel dilution measurement for the analysis of used engine oils | |
| Temperature Range | -15 °C (35 °C / 63 °F below ambient temp.) to 120 °C (5 °F to 248 °F) stand alone. No external cooling required. Down to -40 °C (-13 °F) oven temperature with external cooling |
|
| Temperature Stability | 0.1 °C (0.2 °F) | |
| Sample Troughput | Up to 12 samples per hour | |
| Sample Volume | 1 mL (ASTM D6450), 2 mL (ASTM D7094) | |
| Sample Cups | Nickle plated aluminium, stainless steel cups available upon request | |
| Display | Industry proven 8″ color touchscreen | |
| Languages | English, German, French, Spanish, Russian, Chinese Additional langages available upon request |
|
| Interfaces | Built-in PC with Ethernet, USB and RS232 interfaces Direct LIMS connectivity and output to printer or PC Optional input by external keyboard, mouse and barcode / QR-code reader |
|
| Remote Control | Remote service capability via Ethernet interface | |
| PC Software | ERASOFT RCS – remote control Windows software for multi-instrument remote control, convenient data transfer and result analysis | |
| Result Database | Over 100 000 detailed test reports stored in internal memory | |
| Alarm Tracking | All alarm messages are stored in the database together with the results | |
| Operating Conditions | Temperature range 10°C to 40°C Humidity up to 90% RH, non condensing |
|
| Power Requirements | Auto-switching 85-264 V AC, 47-63 Hz, 70 W (multi-voltage power supply) Field application: 12 V/9 A DC (vehicle battery) |
|
| Dimensions / Weight | 22 x 32 x 28 cm (8.7 x 12.6 x 11 in) / 8 kg (17.6 lb) |
Downloads
Download our brochure for more details
Videos
Configuration
ASTM D7094
| AYA-82-22040 | D7094 Sample cup standard (aluminum, nickel plated, 2 ml) |
| AYA-82-22044 | Sample cup carrier |
| AYA-82-22045 | Stirring magnet |
| AYA-82-22046 | Disposable pipettes (5 pcs.) |
| AYA-82-22047 | Brass eraser |
| AYA-82-22056 | Cleaning tools for electrodes and oven surface |
| AYA-82-22086 | Power cable |
ASTM D6450
| AYA-82-22041 | D6450 Sample cup standard (aluminum, nickel plated, 1 ml) |
| AYA-82-22044 | Sample cup carrier |
| AYA-82-22045 | Stirring magnet |
| AYA-82-22046 | Disposable pipettes |
| AYA-82-22047 | Brass eraser |
| AYA-82-22056 | Cleaning tools for electrodes and oven surface |
| AYA-82-22086 | Power cable |
Tags
Related
eStore
You May Also Like
-
2-pen circular chart recorder CIR-2 with (2) PX pressure sensors
-
2D Barcode / QR Code scanner preconfigured for the use with eralytics products AYA-82-22333
-
Air pump
-
Anisole - Flash Point Standards - 1L
-
Anti-vibration plate for vibration and disruption free mounting in a mobile labo
-
Barcode scanner preconfigured for the use with eralytics products
-
Brass eraser
-
Case latch
-
Cell carrier
-
Cell stopper
-
Ceramic
-
CFPP Vacuum Control Jars
-
Cleaning tools
-
Cooling block for rapid cooling of sample cup
-
Cooling cup
-
D6450 Sample cup standard
-
D7094 Sample cup standard
-
DC Adapter
-
DR7
-
ERAFLASH stirring motor
-
Ethernet cable for data exchange via Internet
-
Glass stopcock
-
Glass syringe 20 ml
-
Ground electrode
-
Instrument metal casing
-
IPC display cable (290mm, for 8" display assembly)
-
Lead Corrosion Beaker
-
Metal pressure cylinder
-
Oven temperature sensor
-
Peltier element
-
Pipette Tips (96 pcs.) for EF01-A012 1ml automatic pipette
-
Disposable Pipettes
-
Pressure Hydrometer Cylinder with Base
-
Processor board including IPC (programmed for ERAFLASH software version 7) - ATT
-
Protective film for touch display
-
Sample cup carrier
-
Sample holder metal pin
-
ERAFLASH sample temperature sensor
-
Stirring Magnet
-
Stylus for data entry via touch display
-
Vacuum pump (as per Section 6.1.12) (220 volt)
-
Vibrator (115 VAC) | Laboratory Vibrator | Silica Gel Packing
-
Water Washout
-
Wifi dongle (for instruments with 8 display)