Eravap
Highly precise vapor pressure tester for fuels, solvents, and crude oils.
Key Features:
- Fast measurement with high repeatability
- Wide temperature range for diverse applications
- Compact design for laboratory and mobile use
- Simple operation with user-friendly touchscreen interface
- Meets different standards
ASTM, D323, D4814, D5191, D6378, D2533, D5482, D2879, D910, D1267, D4953, D5188, D5190, D6377, D6897, IP, 394, 409, 481
Introducing the ERAVAP: Advanced vapor pressure testing for efficient and reliable analysis
The ERAVAP is a highly precise, compact, user-friendly Reid Vapor Pressure (RVP) and Dry Vapor Pressure Equivalent (DVPE) tester. The premier versatile solution for RVP products ranging from fuels to solvents to fragrances and even aqueous solutions. The ERAVAP's precision ensures reliable volatility specification in compliance testing, refining stream quality follow-up, fuel blending, and a wide variety of research and mobile applications.
This device is designed for the everyday user and is fully automated, with minimal operator interactivity.
A small footprint, navigable interface, rugged aluminum casing, and simple operations make the ERAVAP a desirable unit for both laboratory and on-the-go vapor pressure testing. A 10-position autosampler add-on allows maximized, high-volume testing while retaining the ERAVAP's mobility characteristics.
This device is fully compliant with ASTM D5188, D5191, D6378, and EN 13016 making it the ideal unit for R&D, QC, and many more applications using a single analyzer.
Applications of the ERAVAP Include:
Gasoline performance analysis
Emission regulations compliance
Seasonal vapor lock avoidance
Nature of refinery feedstocks
Key Measuring Parameters:
Volatility: DVPE/RVPE measurement describing volatility profile
Pressure Distribution: Gas (Pgas), absolute (Pabs), and total (Ptot) pressure measurements for each sample
Vaporization Tendency: V/L ratio gives insight into the tendency of fuel to vaporize in an engine
The ERAVAP is backed by a comprehensive 1-year warranty, with an option to extend coverage for an additional year upon compliance with the manufacturer’s terms.
For more information or to request a quote, please click here.
For other related devices see the ERAVAP ONLINE or ERAFLASH.
Features
ASTM
CompliantFully compliant to ASTM D4052, D5191, D6378, and D5188
Multilingual AccessibilityMultilingual Accessibility: Operation and output capabilities in the following languages: English, Spanish, Portuguese, Russian, Chinese (coming soon), French (coming soon)
Streamlined OperationStreamlined Operation: An intuitive menu structure ensures seamless user navigation
Maximized ThermoregulationSingle analyzer high speed heating and cooling using patented Peltier Boost Technology
Extensive
DatabaseExtensive Database: Over 100,000 test reports can be stored in the in-unit database
Fully
PortableFully Portable: An accessible design that is lightweight and has an integrated carrying handle allows for suitable and smooth mobility
Enhanced Output EfficiencyEnhanced Output Efficiency: Direct ethernet and LIMS connectivity and in unit result transfer to reports and email
Optional
AutosamplerOptional Sampler: A 10-position autosampler can be added on to maximize testing volume and time
Unparalleled
Repeatability An innovative measurement cell maximizes precision with a self-lubricating piston drive, integrated shaker-motor, and contamination-preventing solenoid valves
Titratable
VersatilityWith a V/L ratio from 0.02/1 to 100/1, a temperature range from 0-120°C, single and multi-point and V/L curve measurements, a pressure range from 0 to 2000 kPa, and customizable measuring programs the unit is exceptionally versatile
Accessories
The following accessories are recommended for purchase in sequential order (see eStore):
1st Year: | No spare parts are required |
2nd Year: | Sampling tube with Luer connector Sampling tube 0,5m with Luer connector Teflon o-ring for EV01-A002a Mesh inlet filter 80µ Outlet tube Kalrez O-ring for pressure sensor (Kalrez 12.42×1.78) O-ring small for measuring cell cover (Viton 6×1.5) |
Remaining Parts: |
Specs
Specifications | ASTM D910, D4814, D6227, EN 228 | |
Available Test Methods | ASTM D5188, D5191, D6377, D6378, D6897 excellent correlation to D323, D4953, D5190, D5482, D1267 EN13016-1 & EN13016-2, IP394, IP409, IP481 JIS K2258-2, SHT 0769, GOST 52340; customized measuring programs |
|
Vapor-Liquid ratio | Variable from 0.02/1 to 100/1, single and multi-point & V/L curve measurements | |
Temperature range | 0°C to 120°C (32 to 248 °F); Peltier technology, no external cooling necessary | |
Temperature Stability | 0.01°C (0.014°F) | |
Temperature profiles | Single temperature, stepped or ramped | |
Pressure range | EV01 ERAVAP: 0 to 1000 kPa (0 to 145 psi) EV02 ERAVAP LPG: 0 to 2000 kPa (0 to 290 psi) | |
Pressure resolution | 0.01 kPa; Accuracy: 0.2 kPa (0.028 psi) | |
Pressure units (selectable) | hPa, kPa, psi, mmHg, bar, mbar, at, atm | |
Precision | Repeatability: r = 0.3 kPa, Reproducibility: R = 0.7 kPa | |
Sample introduction | Automated via built in piston, no external vacuum pump required | |
Measuring time | 5 minutes for a standard measurement | |
Shaker motor | Built-in shaker motor for fast crude oil & T(V/L) measurements | |
D5191 & D5188 Speed test | VP & T(V/L=20) measurement of gasoline at the push-of-a-button | |
Measuring chamber | Nickel plated aluminum chamber | |
Sample volume | 1 ml (2.2 ml per rinsing cycle) | |
Cleaning | By next sample or solvent | |
Display | Industry proven 7’’ color touch screen | |
Remote Control | Remote service capability via Ethernet interface | |
Interfaces | Built-in PC with Ethernet, USB and RS232 interfaces; direct LIMS connectivity and output to printer or PC | |
Auto sampler | Optional 10 position auto sampler – directly attached! | |
Quality-Check tracking | Statistical quality assurance & graphical control charting (ASTM D6299) | |
Result database | > 100,000 detailed test reports stored in internal memory: DVPE, RVPE, PABS, PGAS, PTOT, ASVP & AVP, T(V/L), VLI, TVP | |
Operators | Unlimited operator names memorized | |
Hazy mark | Results can be marked for hazy appearance | |
Sample container size record | 100 ml, 250 ml, 1 l | |
Alarm tracking | All messages are stored in the database together with the result | |
Automated calibration routine | 10-point probe offset correction table, calibration history tracking, self-diagnostics | |
Power requirements | Auto switching 85-264 V AC, 47-63 Hz, 100 W (multi-voltage power supply) Field application: 12 V/9A DC (vehicle battery) |
|
Dimensions / Weight | 22 x 32 x 28 cm (8.7 x 12.6 x 11 in) / 8 kg (17.6 lb) |
Downloads
Download our brochure for more details
Videos
Configuration
ASTM D5191
AYA-82-22081 | Sampling tube (Tygon) 0,3m with Luer connector |
AYA-82-22237 | Mesh inlet filter 80µ (5 pcs, 1 pc inside Sample inlet on instrument) |
AYA-82-22084 | Outlet tube |
AYA-82-22085 | Waste container |
AYA-82-22086 | Power cable |
ASTM D6378
AYA-82-22081 | Sampling tube (Tygon) 0,3m with Luer connector |
AYA-82-22237 | Mesh inlet filter 80µ (5 pcs, 1 pc inside Sample inlet on instrument) |
AYA-82-22084 | Outlet tube |
AYA-82-22085 | Waste container |
AYA-82-22086 | Power cable |
Tags
Related
eStore
You May Also Like
-
1 meter inlet tube
-
Anti-vibration plate for vibration and disruption free mounting in a mobile labo
-
Barometer (Handheld Barometer & Altimeter; ±0.025% F.S.(F.S. = 900 mm Hg abs) in
-
Case latch
-
Cleaning procedure manual (2 pages) for Crude oil (only for EV01 EV01-D6377)
-
DC Adapter
-
ERAVAP -DENSITY
-
Explorer Case for eralytics instruments (generation 8)
-
Glass syringe 20 ml
-
Hydrometer Test Apparatus for Sale
-
Inlet tubing closed filling system
-
Mesh inlet filter 80 (5 pcs)
-
nPentane - 1 L bottle: n-Pentane is primarily used for RVP Calibration Standards per ASTM D5191, D63
-
Pentane - 6 x 1L
-
Portable Density Meter for ERAVAP
-
Protective film for touch display
-
Sampling tube 1,5m with Luer connector
-
Sampling tube with 1 x EV01-A033 Quick-connector and 1 x EV01-A033a Quick-connect
-
Sampling tube with Luer connector
-
Shaker motor for measuring cell
-
Solenoid valve
-
Stylus for data entry via touch display
-
TVS™ Temperature Verification Sensor for ASTM D5191 Testing
-
USB cable for connection to USB printer
-
Vaccuum Pump
-
Waste container