+ 312.476.9292
Log In
Cart
cleveland-flash-point-0500600630 zoom

cleveland-flash-point-0500600630
Full Screen

Cleveland-COC Flash and Fire Point Apparatus

Flash and fire point testing doesn’t get any easier
Methods:
ASTM D92, DIN 51 376, EN 22592, IP 36, ISO 2592,

								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								
								ASTM D92, 
								
								
								
								
								
								DIN 51 376, 
								
								EN 22592, 
								
								
								
								
								
								IP 36, 
								
								ISO 2592, 
								
								
								
								
								
								
								
								

Regulation compliant, quality assured.

The versatile design of Ayalytical Instruments Cleveland-COC Flash and Fire Point apparatus guarantees compliance with ASTM D92, DIN 51 376, EN 22592, IP 36, and ISO 2592, for determining flash and fire points via Cleveland open-cup test methods. This flash and fire point apparatus is ideal for use with all petroleum-based products with flash points between 79º-400ºC, with the exception of fuel oils.

The simple-to- operate Cleveland-COC apparatus is available in four models to meet all your testing needs:

• Model 880 – Cleveland with manual passing on the cup

• Model 890 – Cleveland with automatic passing on the cup, as controlled via internal timer

• Model 880/SEM – Cleveland semi-automatic

• Model 880/AUT – Cleveland automatic with automatic flash point sensor and atmospheric pressure sensor

Built to last, all models feature a smooth anti-acid epoxidic coat, preventing corrosive damage over time. Samples are heated quickly and steadily via electronic regulator, ensuring optimal testing procedures in compliance with multiple aforementioned regulations. All models come equipped with calibrated brass test cup, gas ignition device with pivot function for adjustment during flame application, and pincers for maintenance of thermometer positioning. This open-cup instrument is easily transportable, making it ideal for safe use in the field as well as the laboratory.

features__astm compliant

Models    Positions
Model 880   CLEVELAND With manually passing on the cup
Model 890   CLEVELAND With automatic passing on the cup by internal timer
Model 880/SEM   CLEVELAND SEMI-AUTOMATIC Without automatic flash point sensor and atmospheric pressure sensor
Model 880/AUT    CLEVELAND AUTOMATIC With automatic flash point sensor and atmospheric pressure sensor

The following accessories are recommended for purchase in sequential order (see eStore):

1st Year:
ELECTRIC IGNITOR x4
2nd Year:
Same as 1st year
Remaining Parts:
GAS CYLINDER 2 kg Empty
GAS REDUCER 30 mbar
GAS TUBE, L=5 m
GLASS PT100 PROBE CERTIFIED
THERMOMETER ASTM 11C IP 28C
TUBE, L=3 m
BRASS TEST CUP
CENTERING RING FOR TEST CUP
TEST FLAME APPLICATOR
CLAMP FOR THERMOMETER
HEATER
BIPOLAR GREEN SWITCH
BIPOLAR YELLOW SWITCH
ELECTRONIC REGULATOR
TIMER
GLASS PT100 PROBE CERTIFIED
SAFETY PIVOT THERMOCOUPLE (For 880/AUT)
TEMPERATURE THERMOCOUPLE (For 880/AUT)
TRANSFORMER
THERMOCOUPLE (For 880/AUT)
Test Method Compliance   ASTM D92 DIN 51376 IP 36 EN 22592 ISO 2592
    CLEVELAND With manually passing on the cup, CLEVELAND With automatic passing on the cup by internal timer
Temperature   from 79 to 400°C (from 175 to 752°F)
Power supply   230V ±10% 50Hz
Power   700W
Weight    8 kg
Dimensions   29x33x30 cm
    CLEVELAND SEMI-AUTOMATIC, CLEVELAND AUTOMATIC
Temperature   from 79 to 400°C (from 175 to 752°F)
Power supply   230V ±10% 50Hz
Power   700W
Weight   20 kg
Dimensions   46x31x57 cm
Shipping weight    
Dimensions with crate    

 

Categories:
, , , , , , , , , , , , , .